Le SensorManager de movisens fournit une simple interface et vous permet de travailler facilement avec votre capteur. Il vous permet de voir en détail la configuration du capteur, de lancer des enregistrements (il est également possible d’enregistrer en différé) et de récupérer les données saisies par le capteur. Il accepte et précise aussi si il est nécessaire d’installer de nouveaux micrologiciels.

Nouveaux caractéristiques:
  • Multi-Part-Measurement: If the battery level of the sensor is getting lower than 10%, the measurement will be paused. The LED stops flashing. You can connect the sensor to a USB charger and recharge the battery. If you disconnect the sensor from charger after battery level is higher than 30%, the measurement will be restarted.
  • No measurement stop:  If you reconnect the sensor after starting a measurement again with a PC, the measurement won’t be stopped.
  • Checking battery level: If the battery level of the sensor is less the 10% when clicking on the „Start Recording“ button, the following message appears.
  • Proband configuration: The personal information of the proband can be entered before beginning the measurement. 
Le SensorManager est compatible avec l’ensemble de notre gamme de capteurs physiologiques :
  • Move 4, EcgMove 4, EdaMove 4, LightMove 4
  • Move 3, EcgMove 3, EdaMove 3 LightMove 3
  • Move II, ekgMove, edaMove

Assurez-vous que vous utilisez la dernière version du SensorManager afin de bénéficier d’une amélioration continue et des dernières mises à jours développées pour nos capteurs.

Téléchargements

Newsletter
  • Nous travaillons constamment au développement de nos produits. Afin que vous puissiez bénéficier de ces améliorations, nous vous informerons régulièrement avec notre bulletin d'information. Veuillez vous inscrire ici.
Logiciels
  • SensorManager
  • Veuillez lire le contrat license agreement de manière approfondie. En utilisant le logiciel, vous vous engagez à respecter les clauses de la licence.

Exigences requises pour le système

Le SensorManager requiert:

  • Un PC avec Microsoft Windows 7 ou plus, 64bit
  • Une prise USB
  • Le droit d’administrateur requis durant l‘installation
  • Au minimum 200 MB d’espace libre sur le disque dur

Pour s’améliorer

Download
  • Added shortcut for sensor firmware update
Download
  • Fixed missing new line in sensor log
Download
  • Download of multipart measurements
  • Improved graphical user interface
  • Ask to stop sensor when a started sensor is connected
  • Proband parameter can be set before sensor start
  • Bluetooth can be disabled during measurement
  • Age can be calculated using birthday
  • Write time zone and time offset to sensor before start
  • Fixed GUI freeze when sensor is unpluged right after it is detected
  • Unspecified proband info is not written to unisens
  • Unspecified time zone info is not written to unisens
  • Updated sensor firmware (1.14.2)
    • Multiple measurements can be stored on the sensor
    • Measurement is stopped automatically if battery is less or equal 10%
    • If measurement is stopped because of low battery it is restarted again after the battery is charged to at least 30%
    • Information about the user can be set in the sensor (age, heigt, sensorLocation, etc.)
    • Bluetooth can be disabled on demand
    • Optimized energy consumption of Bluetooth
    • Optional live parameters can be activated via Bluetooth
    • TimeDeviation monitors deviation of time between sensor and smartphone
    • Current time can be set via Bluetooth so the sensor can store timeDeviation
    • Duration of measurement to start can be set via Bluetooth
    • Measurement can be started via Bluetooth even if an older measurement is not downloaded
    • If measurement is stopped via Bluetooth or end is reached all parameters are disabled (to enable parameters disconnect/connect sensor and set indications again)
    • Parameters can be enabled after measurement start via Bluetooth
    • Updated signal processing (fixed altitude, optimized steps, optimized activity recognition, optimized met)
    • Updated met models
    • Updated sensor protocol version (1.34.x)
Download
  • Tolère les erreurs de la connexion USB tout en téléchargeant les données du capteur
  • Évite la mauvaise interprétation de la version du micrologiciel lorsque des caractères sont inclus
  • Trie des paramètres du capteur qui sont affichés selon le type de capteur
  • Évite la troncation d’un mot lorsqu’on utilise un grand champ de texte pour le capteur
  • Un capteur avec un micrologiciel défectueux peut dorénavant être mis à jour
  • Mise à jour 1.12.7 intégrée dans le micrologiciel du capteur
    • L’Unité hr est maintenant 1/min
    • Si la variation de hr n’est pas détectable, hrvRmssd est de 0
    • La mesure ne s’arrète pas même en cas d’erreurs temporaire dans le mode mémoire de masse
    • Il est possible de redébuter la mesure après le débordement de la mémoire de masse
    • Si la mémoire de masse est pleine et que la batterie est faible, la mesure est arrêtée
    • Le stockage de masse est très rapide pour éviter que l’enregistrement ne s’arrête lorsque le Bluetooth est activé
    • Le système Bluetooth se met en mode veille lorsque il est possible d’économiser de la batterie
    • Le nom donné au système Bluetooth pour la quatrième génération de capteur est xMove 4
    • Le capteur désactive automatiquement tous les attributs tamponnés du mode Bluetooth lorsque la mesure est terminée
    • L’attribut supplémentaire de Bluetooth (“Activated Buffered Characteristics”) montre quels attributs tamponnés sont actuellement activés
    • Tous les capteurs avec Bluetooth activé soutiennent tempMean
    • Les capteurs même fortement déchargés s’allument sans problèmes
  • Updated integrated sensor firmware to version 1.11.79